Exposure effects of endotoxin-free titanium-based wear particles to human osteoblasts.

J Mech Behav Biomed Mater. 2019; 
CostaBruna C,AlvesAlexandra C,ToptanFatih,PintoAna M,GrenhoLiliana,FernandesMaria H,PetrovykhDmitri Y,RochaLuís A,Lisboa-FilhoPau
Products/Services Used Details Operation
Proteins, Expression, Isolation and Analysis 125 EU/mL (ToxinSensor Single Test Kits, GenScript), according to the manufacturer recommendations.... Two additional experimental groups, exposed to endotoxins at 50 or 100 ng/mL (corresponding to 500 and 1,000 EU/mL) prepared from control standard endotoxin (CSE, 15 EU/mL, GenScript), were included. Get A Quote

摘要

Titanium-based materials are widely employed by the biomedical industry in orthopedic and dental implants. However, when placed into the human body, these materials are highly susceptible to degradation processes, such as corrosion, wear, and tribocorrosion. As a consequence, metallic ions or particles (debris) may be released, and although several studies have been conducted in recent years to better understand the effects of their exposure to living cells, a consensual opinion has not yet been obtained. In this work, we produced metallic-based wear particles by tribological tests carried out on Ti-6Al-4V and Ti-15Zr-15Mo alloys. They were posteriorly physicochemically characterized according... More

关键词

Biological effects,Degradation,Endotoxins,Titanium implants,Wear parti